Envoyer le message
Aperçu Produitscontrôleur de pH ORP

Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC

Certificat
LA CHINE Suzhou Delfino Environmental Technology Co., Ltd. certifications
LA CHINE Suzhou Delfino Environmental Technology Co., Ltd. certifications
Je suis en ligne une discussion en ligne

Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC

Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC
Differential Signal Input RS485 Online PH ORP Controller 100 ~ 240V AC
Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC

Image Grand :  Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC

Détails sur le produit:
Lieu d'origine: La Chine
Nom de marque: Daruifuno
Certification: CE
Numéro de modèle: APX1-G2A
Conditions de paiement et expédition:
Quantité de commande min: Négociable
Prix: Negotiable

Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC

description de
Nom de produit: contrôleur de pH ORP Plage de pH: -2 | 16pH
Gamme d'ORP: ± 2000mV Température ambiante: -10~150℃/14~302℉
Résolution: 0.01pH/1mV/0.1℃ Écran d'affichage: Affichage à cristaux liquides 128*64
Contrôle de relais: 2 relais de SPST Catégorie de protection: IP66
Température de fonctionnement: 0~60℃ Alimentation d'énergie: 100 | C.A. 240V
Puissance: 3W Poids: 500G
Surligner:

2000mV PH ORP Controllers

,

100V AC ph orp transmitter

,

240V AC PH ORP Controllers

 

Differential Signal Input RS485 Online PH ORP Controller 100 ~ 240V AC

 

The pH ORP controller APX1-G2A is an instrument that continuously monitors the pH and ORP of a solution. It is used for continuous measurement of industrial processes and has both alarm and control functions. The pH of the neutral solution is 7, the pH of the acidic solution is less than 7, and the pH of the alkaline solution is greater than 7. By measuring the pH value of the wastewater, it is possible to determine the current pH of the solution, and then determine the amount of neutralizer to choose and how much to choose, so that the wastewater treatment process can be more clear.

 

Product Introduction

  • The measurement principle is the pH glass electrode measurement method;

  • Large-screen LCD display, Chinese and English language selection, the screen displays the pH value, temperature, electrode type, relay status, and other parameters;

  • The PH ORP controller with differential signal input is compatible with the DRFN pH sensor with grounded electrode;
  • The housing protection grade is IP66, it can effectively isolate the pollution of the external environment;
  • There are 2 SPST multifunction relays that can be set;
  • There is a two-wire RS485 interface, the communication protocol is standard MODBUS RTU, and it also supports JavaScript Object Notation text data format.

 

Product Parameters

 

Product Name

PH ORP controller

Product Model APX1-G2A
Software Version

DRFN PH Analysis software V1.0

PH Range

-2~16pH

ORP Range ± 2000mV
Temperature Range

-10~150℃ /14~302℉

Resolution

0.01pH / 1mV/ 0.1℃

Accuracy

PH:±0.02 pH /ORP:±2 mV

Stability

0.05% of the measurement range per 24 hours, no accumulation

Sensor Diagnosis

Screen image display with a short buzzer alert

Analog Current Output

2 settable 0/4~20mA active current loop output

Relay Control

2 settable SPST relays

Communication Method RS485  MODBUS RTU

Screen Display

128 * 64 LCD

Operating Environment

0~60℃, RH< 95%

Storage Environment

-20~70℃, RH < 55%

Power Supply 100~240V AC
Power Consumption 3 W

Size

100×100×120 mm (hole size 92*92mm)

Weight 500g

Mounting Method

Panel installation

Differential Signal Input RS485 Online pH ORP Controller 100 ~ 240V AC 0

Advantages Of The PH ORP Controller

 

1.The pH meter is with a differential signal, the measurement is more stable, and the anti-interference ability is stronger.

 

2.As the temperature of the aqueous solution changes, the concentration of hydrogen ions and hydroxide ions ionized from the aqueous solution will also change. This instrument has a temperature automatic compensation function, and when the temperature of the instrument changes, it will also compensate the hardware changes caused by temperature drift.

 

Applications Of The PH ORP Controller

 

Water treatment monitoring: Drinking water, surface water, water quality, groundwater, swimming pool, etc.

 

Industrial process monitoring and dosing control management: Chemical, petroleum, paper, food and medicine, electroplating, PCB manufacturing, etc.

 

Suitable Sensor Recommendation

 

 

If you are interested in the product PH ORP controller APX1-G2A, please contact us.

 

 

 

 

Coordonnées
Suzhou Delfino Environmental Technology Co., Ltd.

Personne à contacter: Ms. Yuki Fu

Téléphone: +8615716217387

Envoyez votre demande directement à nous (0 / 3000)